• Hospital Equipments 8inch Vital Signs Patient Monitor Tabletop Multi-Parameter Monitor
  • Hospital Equipments 8inch Vital Signs Patient Monitor Tabletop Multi-Parameter Monitor

Hospital Equipments 8inch Vital Signs Patient Monitor Tabletop Multi-Parameter Monitor

Certification: CE, ISO13485
Size: 175mm×210mm×80mm
Net Weight: 1350g
Display: TFT LCD
Capacity: 3-5 Hours
Transport Package: Standard Export Carton
Samples:
US$ 250/Piece 1 Piece(Min.Order)
| Request Sample
Gold Member Since 2023

Suppliers with verified business licenses

Trading Company
  • Overview
  • Product Description
  • Product Parameters
Overview

Basic Info.

Model NO.
JR2000B
Specification
2pcs/35x35x38cm/ctn
Trademark
Goodwish
Origin
China
Production Capacity
50000PCS/Month

Product Description

Product Description
1,Waterproof design appearance,low power consumption,without air fan and silence,use 13-20V output DC,battery working time is at least 4hours,recharge time is 2.5hours.Suitable for medical field rescue,ambulance,move and transit.
2,display mode of big font,trend review,ECG 7 lead,support one key operation,touchable screen is optional.Suitable for all working places,can used for neonate,child,adult,support mode of diagnose,monitor,operation.
3.13 type arrhythmic analysis,7-lead ECG waveform display in phase. 15 type drug calculation and titration table.
4,efficient resistance to interference of defibrillator and electrosurgical cautery,respiration can choose I\II,meet requirement of operation,ward.
5,use digital SpO2 technology,can test for 0.1% weak,high accuracy.
6,anti-ESU,anti-defibrillator,RA-LL impedance respiration,digital filtering.
7,double over-pressure NIBP protect,temperature drift.
Product Parameters
1.ECG
Lead mode:  3-lead or 5-lead cable
3-lead:RA,LA,LL,lead way:I,II,III
5-lead:RA,LA,LL,RL,V,lead way:I,II,III,aVR,aVL,aVF,V
gain:  ´250,´500,´1000,´2000
Heart rate range:adult:15 ~ 300bpm (pulse/min.)     neonate/child:15 ~ 350 bpm(pulse/min.)
accuracy:±1% or ±1bpm,
resolution:1 bpm(pulse/min.)
sensitivity  >200 uV(peak-to-peak value)
Input resistance >5(mge)
bandwidth:
Diagnostic mode:0.05~130Hz
Monitor mode:0.5~40Hz
Operation mode:1~20Hz
Common mode rejection ratio
Diagnostic mode:>90 dB
Monitor mode:>100 dB
Operation mode:>100 dB
The electrode polarization voltage range  ±300mV
Pacemaker pulse detection
Can test following:
range:±2 mV ~ ±700mV
width:0.1ms ~ 2ms
rise time:10us~100µs
Pacemaker pulse suppression
When turn on pacemaker pulse,can restrain following data, does not influence pulse rate calculation:
range:±2 mV ~ ±700mV
width:0.1ms ~ 2ms
rise time:10us ~ 100µs
Baseline recovery time after defibrillation< 3 seconds
Sign range ±8 mV (peak-to-peak value)
Calibrating signal 1mV(peak-to-peak value),accuracy         ±5%
ST measurement
Measure range:-2.0mV ~ +2.0mV
Measure accuracy:in range of -0.8 mV~+0.8mV  the tolerance is  ±0.02mV or ±10% take bigger one.
Undefinition in other range.
2.Respiration
Way:  RA-LL impedance and RA-LA impedance.
Range: 0.3~
Base impedance range 200~4000Ω
Band width 0.1~2.5Hz
Respiration rate
range adult:2~120BrPM   child and neonate:2~150 BrPM
resolution:1 BrPM
accuracy:±2 BrPM
Apnea alarm 10~40 seconds
3.NIBP
Technology:Oscillometric
Mode: manual/auto/STAT
Measurement inerval time under auto mode is 1,2,3,4,5,10,15,30,60,90,120,180,240,480 minutes.
Measurement time under STAT mode is  5 minutes.
Pulse rate range   40~240 bpm
Measurement range and accuracy
range
adult     SIS                40~270mmHg
                                DIA              10~215mmHg
                                mean 20~235mmHg
child     SIS                40~200mmHg
                                DIA              10~150mmHg
                                mean 20~165mmHg
                        neonate            SIS                   40~135mmHg
                                                   DIA              10~100mmHg
                                                   mean 20~110mmHg
Static pressure range        0~300mmHg
Static pressure accuracy ±3mmHg
Blood pressure accuracy:                      maximum average error           ±5mmHg;largest standard deviation           8mmHg
Over-pressure protect
Adult mode                          300 mmHg
Child mode                       240 mmHg
Neonate mode                  150 mmHg
4.SpO2

range                     0~100%
resolution                         1%
accuracy                           70~100%:±2;0%~69%:undefinition
Pulse rate
range                     20~300bpm
resolution                         1bpm
accuracy                           ±3bpm
5.TEMP
Suitable temperature probe  YSI,CYF
Channel number:  1 channel
range    0~50°C  resolution    0.1°C   accuracy          ±0.1°C(do not include error of probe)

Standard accessories

main unit 1
5lead ECG cable with clip 1
NIBP extend tube 1
NIBP cuff for Animal 5
SpO2 probe for Animal 1
Rectal TEMP probe 1
Power Wire 1
User manual in English 1

 

Hospital Equipments 8inch Vital Signs Patient Monitor Tabletop Multi-Parameter MonitorHospital Equipments 8inch Vital Signs Patient Monitor Tabletop Multi-Parameter MonitorHospital Equipments 8inch Vital Signs Patient Monitor Tabletop Multi-Parameter MonitorHospital Equipments 8inch Vital Signs Patient Monitor Tabletop Multi-Parameter Monitor