Certification: | CE, ISO13485 |
---|---|
Optional: | : Touchscreen, VGA, 2-IBP, HDMI, Etco2 |
Parameter: | ECG,Resp,NIBP,SpO2,Pr/Hr,Temp |
Still deciding? Get samples of US$ 250/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
1. Standard parameters:ECG,RESP,NIBP,SPO2,PR/HR,TEMP.
2.13 types Arrhythmic Analysis, Multi-lead ECG waveforms display in Phase, 15 types Drug calculation and titration table. 3.Anti-ESU, anti-defibrillator; RA-LL impedance. 4.SPO2 can testing for 0.1% weak,high accuracy. 5.Unique breathing measurement technology, real-time monitoring, intelligent filter design, eliminate interference, measuring respiratory accurately. 6.Trend Coexist interface for all parameter to observe easily. 7.OxyCRG Dynamic View display, More intultive with all parameters. 8.Platform scalable with cable or wireless connecting to central monitoring. 9.Printer /Recorder is optional for real-time printing. 10.Brief operation interface, Touchscreen is optional. Up to 2-5 hours working capacity of built-in rechargeable Li-ion battery.
11. 12.1"high resolution color TFT LCD display.
12. Holographic waveform trends playback for 2 weeks and 12 hours off electricity saving. 13.Built-in networking to realize central monitoring function.
14.Optional: Touchscreen, VGA, 2-IBP, HDMI, ETCO2.å 15.System start up only need 10 seconds with ARM-A5 Nuclear technology. |
ECG Lead Mode: 5 Leads or 3 Leads 3 Leads:RA,LA,LL,Lead mode:I,II,III 5 Leads:RA,LA,LL,RL,V,Lead mode:I,II,III,aVR,aVL,aVF,V Gain ´250,´500,´1000,´2000 Heart Rate : Range: Adult:15 ~ 300bpm ; Neonate / Pediatric:15 ~ 350 bpm Accuracy:±1%or ±1bpm, Resolution:1 bpm Sensitivity >200 uV Differential Input Impedance >5MΩ Bandwidth Diagnostic:0.05~130Hz Monitor:0.5~40Hz Surgery:1~20Hz
RESP
Method: Impedance between R-F(RA-LL) Scope of base impedance:200~4000Ω Bandwidth: 0.1~ 2.5 Hz Range: Adult:2~120BrPM Neonate / Pediatric :2~150 BrPM Resolution:1 BrPM Accuracy:±2 BrPM Suffocation warning:10~40s NIBP Method: Oscillometric Mode: Manual, Auto, STAT Measuring interval in AUTO MODE:1,2,3,4,5,10,15,30,60,90,120,180,240,480 MINS Measuring interval in STAT MODE 5 MINS PR range 40~240 bpm Measuring Range and Resolution Adult SYS 40~270mmHg DIA 10~215mmHg MEAN 20~235mmHg PED SYS 40~200mmHg DIA 10~150mmHg MEAN 20~165mmHg NEO SYS 40~135mmHg DIA 10~100mmHg MEAN 20~110mmHg STATIC NIBP range: 0~300mmHg Static NIBP accuracy:±3mmHg Max Average tolerance ±5mmHg;Max. Standard tolerance: 8mmHg Over-pressure protection: Adult mode: 300 mmHg Ped mode: 240 mmHg Neo mode: 150 mmHg
SpO2
Measuring range: 0~100% Resolution: 1% Accuracy: 70~100%:±2;0%~69%: Pulse Rate: Measuring range: 20~300bpm Resolution: 1bpm Accuracy: ±3bpm
TEMP
Channels: 2 Measuring: Range: 0~50°C Resolution 0.1°C Accuracy : ±0.1°C(sensor tolerance no not included ) 6. Power Adapter Input:AC 90 V~240V, 50/60Hz Output:DC 12V-20V Built-in Battery: TYPE:14.8V, 2200mAH Li-ion rechargeable battery Operating time:3.5-4 hours working time under full power Charging time:2 hours
Measuring and alarm range ART 0 ~ 300 mmHg, PA -6 ~ 120 mmHg CVP/RAP/LAP/ICP -10 ~ 40 mmHg , P1/P2 -10 ~ 300 mmHg Press Sensor Sensitivity 5 uV/V/mmHg, Impedance 300-3000Ω Resolution 1 mmHg Accuracy ±2% or ±1mmHg, which great Actualization interval about 1 Sec. 8. CO2(Optional)Measuring and alarm range 0% ~ 13%Resolution 1 mmHg Accuracy 2 mmHg @ < 5.0% CO (at ATPS) RR 3 - 150 bpm |
Standard accessories
main unit | 1 |
5lead ECG cable | 1 |
NIBP cuff for adult with extend tube | 1 |
SpO2 adult finger probe | 1 |
Surface TEMP probe | 1 |
Power Wire | 1 |
User manual in English | 1 |